Table 4.6          Cumulative Construction Noise Levels at Representative NSRs (Without Mitigation)

 

NSRs

Maximum Noise Level, dB(A)

Cumulative Noise Levels, dB(A)

 

P1a

P1b

P2

Sewer

Submarine Outfall

CMV1

81.4

64.7

--

102.0

--

102

CMV2

89.4

77.7

--

99.5

--

100

CMV3

70.6

76.7

--

91.5

--

92

CMV4

82.7

82.7

--

89.9

--

91

CMV5

83.7

77.7

--

95.9

--

96

CMV6

87.5

77.4

--

95.9

--

97

THT

70.8

74.9

--

95.9

--

96

SKW1

69.4

72.4

--

99.5

--

100

SKW2

68.5

61.8

58

99.5

--

100

SKW3

--

59.9

59

102.0

--

102

SKW4

--

58.3

60

102.0

--

102

SKW5

--

--

62

85.5

--

86

SKW6

--

--

65

79.9

--

80

SKW7

59.0

72.2

--

79.9

--

81

SKW8

57.5

70.1

59

79.9

--

80

SKW9

--

68.6

60

79.9

--

80

SKW10

--

--

74

105.5

--

106

SKW11

--

--

75

95.9

--

96

SKW12

--

--

77

102.0

 

102

TSW1

--

--

84

95.9

--

96

TSW2

--

--

76

91.5

--

92

TSW3

--

--

74

95.9

--

96

TSW4

--

--

72

99.5

--

99

MTW1

--

--

--

65.9

67.1

70

MTW2

--

--

--

63.9

65.1

68

Note:

3 dB(A) facade effect was added in the calculation

--   The noise level at this particular NSR was negligible as it would be more than 300m away from the construction activity.

Boldface indicates an exceedance of the noise criteria of 75dB(A) for residential uses and 70dB(A) for Temple and library.