Appendix 4.4
Assumed Operation Equipment for STW 
Powered Mechanical Equipment Reference No. Items SWL/Item Screening* Sub-total Total SWL Total SWL
(PME)     dB(A) dB(A) SWL dB(A) dB(A) dB(A)
Equalisation transfer pump CNP 283 1 85   85    
Effluent lift pump CNP 283 1 85   85    
Sludge recycling pump CNP 283 2 85   88    
Sludge wasty pump CNP 283 2 85   88    
Sludge pump CNP 283 1 85   85    
Air blower estimate1 1 102   102    
Filter press estimate1 1 94   94    
Deodouriser estimate1 1 79   79 10 103.28
Assumed Operation Equipment for Pumping Stations P1a, P1b and P2 (Unmitigated)
Powered Mechanical Equipment Reference No. Items SWL/Item Screening* Sub-total Total SWL Total SWL
(PME)     dB(A) dB(A) SWL dB(A) dB(A) dB(A)
Submersible water pump CNP 283 1 85 10 75    
Deodouriser1 R1 1 79   79 80.5 80.46
Note:
*      Assume 10 dB(A) noise reduction for equipment placing in enclosure
1   Estimated SWLs of the equipment obtained from contractors
1      Based on fan with 1700m3/hr flowrate
R1   Good Practices on Ventilation System Noise Control (EPD)