Appendix 4.9
Predicted Noise Levels from Construction of  Pumping Stations (With the Use of Quiet Equipment)
Pumping Station P1a
Sensitive receiver Distance from Construction Activities,      m Foundation Superstructural Works
Excavation, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A) Backfilling, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A)
SWL 110.7 102.5 106.3 108.0 102.5 106.3
    110.72 102.53 106.258 108.01 102.53 106.26
CMV1 60 70.1 61.9 65.7 67.4 61.9 65.7
CMV2 24 78.1 69.9 73.7 75.4 69.9 73.7
CMV3* 66 59.3 51.1 54.9 56.6 51.1 54.9
CMV4 52 71.4 63.2 66.9 68.7 63.2 67.0
CMV5 46 72.4 64.2 68.0 69.8 64.2 68.0
CMV6 30 76.2 68.0 71.7 73.5 68.0 71.8
THT 204 59.5 51.3 55.1 56.8 51.3 55.1
SKW1 240 58.1 49.9 53.7 55.4 49.9 53.7
SKW2 266 57.2 49.0 52.8 54.5 49.0 52.8
SKW3 -- -- -- -- -- -- --
SKW4 -- -- -- -- -- -- --
SKW5 -- -- -- -- -- -- --
SKW6 -- -- -- -- -- -- --
SKW7* 250 47.7 39.5 43.3 45.1 39.5 43.3
SKW8* 300 46.2 38.0 41.7 43.5 38.0 41.8
SKW9 -- -- -- -- -- -- --
SKW10 -- -- -- -- -- -- --
SKW11 -- -- -- -- -- -- --
SKW12 -- -- -- -- -- -- --
TSW1 -- -- -- -- -- -- --
TSW2 -- -- -- -- -- -- --
TSW3 -- -- -- -- -- -- --
TSW4 -- -- -- -- -- -- --
MTW1 -- -- -- -- -- -- --
MTW2 -- -- -- -- -- -- --
Pumping Station P1b
Sensitive receiver Distance from Construction Activities,   m Foundation Superstructural Works
Excavation, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A) Backfilling, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A)
SWL 110.7 102.5 106.3 108.0 102.5 106.3
CMV1* 130 53.4 45.2 49.0 50.7 45.2 49.0
CMV2 92 66.4 58.2 62.0 63.7 58.2 62.0
CMV3 104 65.4 57.2 60.9 62.7 57.2 61.0
CMV4 52 71.4 63.2 66.9 68.7 63.2 67.0
CMV5 92 66.4 58.2 62.0 63.7 58.2 62.0
CMV6 96 66.1 57.9 61.6 63.4 57.9 61.7
THT 128 63.6 55.4 59.1 60.9 55.4 59.2
SKW1 170 61.1 52.9 56.6 58.4 52.9 56.7
SKW2* 182 50.5 42.3 46.1 47.8 42.3 46.1
SKW3* 226 48.6 40.4 44.2 45.9 40.4 44.2
SKW4* 272 47.0 38.8 42.6 44.3 38.8 42.6
SKW5 -- -- -- -- -- -- --
SKW6 -- -- -- -- -- -- --
SKW7 174 60.9 52.7 56.4 58.2 52.7 56.5
SKW8 222 58.8 50.6 54.3 56.1 50.6 54.4
SKW9 262 57.3 49.1 52.9 54.6 49.1 52.9
SKW10 -- -- -- -- -- -- --
SKW11 -- -- -- -- -- -- --
SKW12 -- -- -- -- -- -- --
TSW1 -- -- -- -- -- -- --
TSW2 -- -- -- -- -- -- --
TSW3 -- -- -- -- -- -- --
TSW4 -- -- -- -- -- -- --
MTW1 -- -- -- -- -- -- --
MTW2 -- -- -- -- -- -- --
Pumping Station P2
Sensitive receiver Distance from Construction Activities,        m Foundation Superstructural Works
Excavation, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A) Backfilling, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A)
110.7 102.5 106.3 108.0 102.5 106.3
CMV1 -- -- -- -- -- -- --
CMV2 -- -- -- -- -- -- --
CMV3 -- -- -- -- -- -- --
CMV4 -- -- -- -- -- -- --
CMV5 -- -- -- -- -- -- --
CMV6 -- -- -- -- -- -- --
THT -- -- -- -- -- -- --
SKW1 -- -- -- -- -- -- --
SKW2* 288 46.5 38.3 42.1 43.8 38.3 42.1
SKW3* 256 47.5 39.3 43.1 44.8 39.3 43.1
SKW4* 212 49.2 41.0 44.7 46.5 41.0 44.8
SKW5* 168 51.2 43.0 46.8 48.5 43.0 46.8
SKW6 * 130 53.4 45.2 49.0 50.7 45.2 49.0
SKW7 -- -- -- -- -- -- --
SKW8* 260 47.4 39.2 43.0 44.7 39.2 43.0
SKW9* 223 48.7 40.5 44.3 46.0 40.5 44.3
SKW10 140 62.8 54.6 58.3 60.1 54.6 58.4
SKW11 120 64.1 55.9 59.7 61.4 55.9 59.7
SKW12 103 65.4 57.2 61.0 62.8 57.2 61.0
TSW1 44 72.8 64.6 68.4 70.1 64.6 68.4
TSW2 118 64.3 56.1 59.8 61.6 56.1 59.9
TSW3 138 62.9 54.7 58.5 60.2 54.7 58.5
TSW4 188 60.2 52.0 55.8 57.5 52.0 55.8
MTW1 -- -- -- -- -- -- --
MTW2 -- -- -- -- -- -- --
Note: 3 dB(A) facade effect was added in the calculation
 --  The noise level at this particular NSR is negligible as it is more than 300m away from the construction activity.
*  Assumed 10dB(A) noise attenuation for NSR which would be totally screened from construction activity
Boldface indicate an exceedance of the noise criteria of 75dB(A) for residential uses and 70 dB(A) for temple and library