Noise Mitigation Measures adopted:
Architectural Fin
Major Noise Source
Target of Protection
Noise barrier
Architectural Fin
Dimension of Fin: | 2-3m wide concrete wall |
---|---|
Noise Reduction: | About 2-4dB(A) |
Vertical Barrier
Major Noise Source
Target of Protection
Noise barrier
Architectural Fin
End Wall: | 10m high and 1m wide cantilevered noise barrier |
---|---|
Materials Selection: | Concrete |