Noise Mitigation Measures adopted:
Noise Tolerant Building / Carpark
Major Noise Source
Target of Protection
Noise Tolerant Building
Innovative Layout
Architectural Fin
Type of Noise Tolerant Building: | Commercial Centre (about 10m high) and a 3m barrier wall on top of Carpark Building (about 13m high) acts as noise shielding structure to protect the residents at the back. |
---|---|
Noise Reduction: | About 5-15 dB(A) |
Building layout/orientation
Major Noise Source
Target of Protection
Noise Tolerant Building
Innovative Layout
Architectural Fin
Innovative Layout: | Noise tolerant portions ( including corridors) are arranged to face the noise source |
---|---|
Noise Reduction: | About 4-10 dB(A) |
Architectural Fin
Major Noise Source
Target of Protection
Noise Tolerant Building
Innovative Layout
Architectural Fin
Architectural Fin: | 1.2-1.5m wide concrete wall |
---|---|
Noise Reduction: | About 1-2 dB(A) |