Skip to main content

Upper Wong Tai Sin Estate

photo of noise barrier
photo of noise tolerant building
Category Information
Target of Protection
Residents in Upper Wong Tai Sin Estate , Wong Tai Sin
Total Number of Flats
4200
Major Noise Sources
Lung Cheung Road and Wong Tai Sin Road
Environmental Gain
All the flats comply with the road traffic noise criterion
Year of Completion
2000
Noise Mitigation Measures adopted:
Building layout/orientation
innovative layout
photo of innovative layout

Major Noise SourceMajor Noise Source

Target of ProtectionTarget of Protection

innovative layoutInnovative Layout

noise tolerant buildingNoise Tolerant Building

noise barrierNoise barrier

end wallEnd Wall

Innovative Layout: Noise tolerant portions ( including corridors and stairwells) are arranged to face the noise source
Noise Reduction: About 5-18 dB(A)
Noise Tolerant Building / Carpark
noise tolerant building
photo of noise tolerant building

Major Noise SourceMajor Noise Source

Target of ProtectionTarget of Protection

innovative layoutInnovative Layout

noise tolerant buildingNoise Tolerant Building

noise barrierNoise barrier

end wallEnd Wall

Type of Noise Tolerant Building: Commercial centre acts as noise shielding structure to protect the residents at the back
Noise Reduction: About 5-10 dB(A)
Vertical Barrier
noise barrier
photo of noise barrier

Major Noise SourceMajor Noise Source

Target of ProtectionTarget of Protection

innovative layoutInnovative Layout

noise tolerant buildingNoise Tolerant Building

noise barrierNoise barrier

end wallEnd Wall

Dimension of Barrier: Vertical barrier: 5m high and 15 m in length; Cantilevered barrier: 8m high with a 1m wide cantilevered panel and 115 m in length
Materials Selection: Concrete
Noise Reduction: About 5 dB(A)
End Wall
end wall
photo of end wall

Major Noise SourceMajor Noise Source

Target of ProtectionTarget of Protection

innovative layoutInnovative Layout

noise tolerant buildingNoise Tolerant Building

noise barrierNoise barrier

end wallEnd Wall

End Wall: End wall is arranged to face the noise source
Noise Reduction: About 2-3 dB(A)