Assessment
Point
Noise
levels shall be determined by carrying out
measurements at the assessment point. Where
a measurement is to be carried out at a
building, the assessment point shall normally
be at a position 1 m from the exterior of
the building facade but may be at any other
point considered to be appropriate by the
Authority. Where a measurement is to be
made of noise being received at a place
other than a building, the assessment point
shall be at a position 1.2 m above the ground,
at a particular point considered appropriate
by the Authority.
Where
the noise under investigation is transmitted
to the NSR primarily either through the
structural elements of the building; through
openings other than those at the facade
of the building; or through specially provided
glazing at the facade of the building as
considers appropriate for reducing the noise,
the assessment point shall be at a particular
internal location which the Authority considers
appropriate having regard to the normal
occupancy of the building.
|