3.
SITE INVESTIGATION
3.4
Sample Size and Handling Procedures
Sample
collection tools should be thoroughly steam cleaned before
and between taking samples. Before sampling commences, the
laboratory should be consulted on the particular sample size
and preservation procedures that are necessary for each chemical
analysis. The sample containers should be laboratory cleaned,
sealable, water-tight, made of glass or other suitable materials
with aluminium or teflon-lined lids, so that the container
surface will not react with the sample or adsorb contaminants.
The containers should be marked with the sampling point codes
and the depths at which the samples were taken. If the contents
are hazardous, this should be clearly marked on the container
and precautions taken during transport. Samples should be
stored between 0 - 4°C but never frozen.
|