Table 4.8          Cumulative Construction Noise Levels at Representative NSRs (With Mitigation)

 

NSRs

Maximum Noise Level, dB(A)

Cumulative Noise Levels, dB(A)

 

P1a

P1b

P2

Sewer

Submarine Outfall

CMV1

65.1

53.4

--

94.1

--

94

CMV2

73.1

66.4

--

91.6

--

92

CMV3

54.3

65.4

--

83.6

--

84

CMV4

66.4

71.4

--

82.0

--

82

CMV5

67.4

66.4

--

88.0

--

88

CMV6

71.2

66.1

--

88.0

--

88

THT

54.5

63.6

--

88.0

--

88

SKW1

53.1

61.1

--

91.6

--

92

SKW2

52.2

50.5

46.5

91.6

--

92

SKW3

--

48.6

47.5

94.1

--

94

SKW4

--

47.0

49.2

94.1

--

94

SKW5

--

--

51.2

77.6

--

78

SKW6

--

--

53.4

72.0

--

72

SKW7

42.7

60.9

--

72.0

--

72

SKW8

41.2

58.8

47.4

72.0

--

72

SKW9

--

57.3

48.7

72.0

--

72

SKW10

--

--

62.8

97.6

--

98

SKW11

--

--

64.1

88.0

--

88

SKW12

--

--

65.4

94.1

--

94

TSW1

--

--

72.8

88.0

--

88

TSW2

--

--

64.3

83.6

--

84

TSW3

--

--

62.9

88.0

--

88

TSW4

--

--

60.2

91.6

--

92

Note:

3 dB(A) facade effect was added in the calculation

--   The noise level at this particular NSR was negligible as it would be more than 300m away from the construction activity.

Boldface indicates an exceedance of the noise criteria of 75dB(A) for residential uses and 70dB(A) for temple and library.