Appendix 4.5
Predicted Noise Levels from Construction of  Pumping Stations (Unmitigated)
Pumping Station P1a
Sensitive receiver Distance from Construction Activities,      m Foundation Superstructural Works
Excavation, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A) Backfilling, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A)
SWL 122.0 102.5 116.5 108.0 102.5 116.5  
    122.05 102.53 116.500 108.01 102.53 116.50
CMV1 60 81.4 61.9 75.9 67.4 61.9 75.9
CMV2 24 89.4 69.9 83.9 75.4 69.9 83.9
CMV3* 66 70.6 51.1 65.1 56.6 51.1 65.1
CMV4 52 82.7 63.2 77.2 68.7 63.2 77.2
CMV5 46 83.7 64.2 78.2 69.8 64.2 78.2
CMV6 30 87.5 68.0 82.0 73.5 68.0 82.0
THT 204 70.8 51.3 65.3 56.8 51.3 65.3
SKW1 240 69.4 49.9 63.9 55.4 49.9 63.9
SKW2 266 68.5 49.0 63.0 54.5 49.0 63.0
SKW3 -- -- -- -- -- -- --
SKW4 -- -- -- -- -- -- --
SKW5 -- -- -- -- -- -- --
SKW6 -- -- -- -- -- -- --
SKW7* 250 59.0 39.5 53.5 45.1 39.5 53.5
SKW8* 300 57.5 38.0 52.0 43.5 38.0 52.0
SKW9 -- -- -- -- -- -- --
SKW10 -- -- -- -- -- -- --
SKW11 -- -- -- -- -- -- --
SKW12 -- -- -- -- -- -- --
TSW1 -- -- -- -- -- -- --
TSW2 -- -- -- -- -- -- --
TSW3 -- -- -- -- -- -- --
TSW4 -- -- -- -- -- -- --
MTW1 -- -- -- -- -- -- --
MTW2 -- -- -- -- -- -- --
Pumping Station P1b
Sensitive receiver Distance from Construction Activities,   m Foundation Superstructural Works
Excavation, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A) Backfilling, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A)
SWL 122.0 102.5 116.5 108.0 102.5 116.5
CMV1* 130 64.7 45.2 59.2 50.7 45.2 59.2
CMV2 92 77.7 58.2 72.2 63.7 58.2 72.2
CMV3 104 76.7 57.2 71.2 62.7 57.2 71.2
CMV4 52 82.7 63.2 77.2 68.7 63.2 77.2
CMV5 92 77.7 58.2 72.2 63.7 58.2 72.2
CMV6 96 77.4 57.9 71.9 63.4 57.9 71.9
THT 128 74.9 55.4 69.4 60.9 55.4 69.4
SKW1 170 72.4 52.9 66.9 58.4 52.9 66.9
SKW2* 182 61.8 42.3 56.3 47.8 42.3 56.3
SKW3* 226 59.9 40.4 54.4 45.9 40.4 54.4
SKW4* 272 58.3 38.8 52.8 44.3 38.8 52.8
SKW5 -- -- -- -- -- -- --
SKW6 -- -- -- -- -- -- --
SKW7 174 72.2 52.7 66.7 58.2 52.7 66.7
SKW8 222 70.1 50.6 64.6 56.1 50.6 64.6
SKW9 262 68.6 49.1 63.1 54.6 49.1 63.1
SKW10 -- -- -- -- -- -- --
SKW11 -- -- -- -- -- -- --
SKW12 -- -- -- -- -- -- --
TSW1 -- -- -- -- -- -- --
TSW2 -- -- -- -- -- -- --
TSW3 -- -- -- -- -- -- --
TSW4 -- -- -- -- -- -- --
MTW1 -- -- -- -- -- -- --
MTW2 -- -- -- -- -- -- --
Pumping Station P2
Sensitive receiver Distance from Construction Activities,        m Foundation Superstructural Works
Excavation, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A) Backfilling, dB(A) Formwork, reinforcement & fixing, dB(A) Concreting, dB(A)
122.0 102.5 116.5 108.0 102.5 116.5
CMV1 -- -- -- -- -- -- --
CMV2 -- -- -- -- -- -- --
CMV3 -- -- -- -- -- -- --
CMV4 -- -- -- -- -- -- --
CMV5 -- -- -- -- -- -- --
CMV6 -- -- -- -- -- -- --
THT -- -- -- -- -- -- --
SKW1 -- -- -- -- -- -- --
SKW2* 288 57.8 38.3 52.3 43.8 38.3 52.3
SKW3* 256 58.8 39.3 53.3 44.8 39.3 53.3
SKW4* 212 60.5 41.0 55.0 46.5 41.0 55.0
SKW5* 168 62.5 43.0 57.0 48.5 43.0 57.0
SKW6 * 130 64.7 45.2 59.2 50.7 45.2 59.2
SKW7 -- -- -- -- -- -- --
SKW8* 260 58.7 39.2 53.2 44.7 39.2 53.2
SKW9* 223 60.0 40.5 54.5 46.0 40.5 54.5
SKW10 140 74.1 54.6 68.6 60.1 54.6 68.6
SKW11 120 75.4 55.9 69.9 61.4 55.9 69.9
SKW12 103 76.7 57.2 71.2 62.8 57.2 71.2
TSW1 44 84.1 64.6 78.6 70.1 64.6 78.6
TSW2 118 75.6 56.1 70.1 61.6 56.1 70.1
TSW3 138 74.2 54.7 68.7 60.2 54.7 68.7
TSW4 188 71.5 52.0 66.0 57.5 52.0 66.0
MTW1 -- -- -- -- -- -- --
MTW2 -- -- -- -- -- -- --
Note: 3 dB(A) facade effect was added in the calculation
 --  The noise level at this particular NSR is negligible as it is more than 300m away from the construction activity.
*  Assumed 10dB(A) noise attenuation for NSR which would be totally screened from construction activity
Boldface indicate an exceedance of the noise criteria of 75dB(A) for residential uses and 70 dB(A) for temple and library