Appendix 4.2 Construction Noise Impact Assessment |
|
|
|
|
|
|
|
|
|
|
|
|
|
(F1) Calculation of Construction Noise Levels
at Representative Noise Sensitive Receivers - Mitigated (Quite Plant+Barrier) |
|
|
|
NSR:
"LUT" |
|
|
|
|
|
|
|
SWL |
Distance |
B.C.* |
CNL |
|
|
|
Cumulative Activities |
|
|
|
Activity |
|
(dB(A)) |
(m) |
(dB(A)) |
(dB(A)) |
(I) |
(II) |
(III) |
(I)+(II) |
(I)+(III)A |
(I)+(III)B |
(I) + (III)C |
(I) Water Mains Construction |
|
|
|
|
|
|
|
A |
Excavation
of Trench / Breaking up Pavement |
102 |
14 |
|
74 |
74 |
- |
- |
- |
- |
- |
- |
B |
Installation of Pipes and Bedding |
98 |
14 |
|
71 |
71 |
- |
- |
- |
- |
- |
- |
C |
Backfilling |
98 |
14 |
|
70 |
70 |
- |
- |
- |
- |
- |
- |
D |
Reinstating Road Surface |
99 |
14 |
|
71 |
71 |
- |
- |
- |
- |
- |
- |
(II) Demolishment of Pui O Raw Water Pumping
Station |
|
|
|
|
|
A |
General Site Clearance / Demolition Works |
114 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
(III) Construction of Pui O Raw Water Pumping
Station |
|
|
|
|
|
A |
Foundation |
113 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
B |
Superstructural Works |
112 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
C |
Installation of E&M Equipment and Commissioning &
Testing |
102 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
|
|
NSR:
"BOS" (During Normal Teaching Period) |
|
|
|
|
|
|
|
SWL |
Distance |
B.C.* |
CNL |
|
|
|
Cumulative Activities |
|
|
|
Activity |
|
(dB(A)) |
(m) |
(dB(A)) |
(dB(A)) |
(I) |
(II) |
(III) |
(I)+(II) |
(I)+(III)A |
(I)+(III)B |
(I) + (III)C |
(I) Water Mains Construction |
|
|
|
|
|
|
|
A |
Excavation
of Trench / Breaking up Pavement |
102 |
24 |
|
70 |
70 |
- |
- |
- |
- |
- |
- |
B |
Installation of Pipes and Bedding |
98 |
24 |
|
66 |
66 |
- |
- |
- |
- |
- |
- |
C |
Backfilling |
98 |
24 |
|
65 |
65 |
- |
- |
- |
- |
- |
- |
D |
Reinstating Road Surface |
99 |
24 |
|
66 |
66 |
- |
- |
- |
- |
- |
- |
(II) Demolishment of Pui O Raw Water Pumping
Station |
|
|
|
|
|
A |
General Site Clearance / Demolition Works |
114 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
(III) Construction of Pui O Raw Water Pumping
Station |
|
|
- |
|
- |
- |
- |
- |
A |
Foundation |
113 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
B |
Superstructural Works |
112 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
C |
Installation of E&M Equipment and Commissioning &
Testing |
102 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
|
|
NSR:
"LWT1" |
|
|
|
|
|
|
|
SWL |
Distance |
B.C.* |
CNL |
|
|
|
Cumulative Activities |
|
|
|
Activity |
|
(dB(A)) |
(m) |
(dB(A)) |
(dB(A)) |
(I) |
(II) |
(III) |
(I)+(II) |
(I)+(III)A |
(I)+(III)B |
(I) + (III)C |
(I) Water Mains Construction |
|
|
|
|
|
|
|
A |
Excavation
of Trench / Breaking up Pavement |
102 |
13 |
|
75 |
75 |
- |
- |
- |
- |
- |
- |
B |
Installation of Pipes and Bedding |
98 |
13 |
|
72 |
72 |
- |
- |
- |
- |
- |
- |
C |
Backfilling |
98 |
13 |
|
71 |
71 |
- |
- |
- |
- |
- |
- |
D |
Reinstating Road Surface |
99 |
13 |
|
72 |
72 |
- |
- |
- |
- |
- |
- |
(II) Demolishment of Pui O Raw Water Pumping
Station |
|
|
|
|
|
A |
General Site Clearance / Demolition Works |
114 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
(III) Construction of Pui O Raw Water Pumping
Station |
|
|
- |
|
- |
- |
- |
- |
A |
Foundation |
113 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
B |
Superstructural Works |
112 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
C |
Installation of E&M Equipment and Commissioning &
Testing |
102 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(F2) Calculation of Construction Noise Levels
at Representative Noise Sensitive Receiver BOS (during examination period) |
|
- Mitigated (Quite Plant+Barrier) |
|
|
|
|
|
NSR:
"BOS" |
|
|
|
|
|
|
|
|
SWL |
Distance |
B.C.* |
CNL |
|
|
|
Cumulative Activities |
|
|
|
Activity |
|
(dB(A)) |
(m) |
(dB(A)) |
(dB(A)) |
(I) |
(II) |
(III) |
(I)+(II) |
(I)+(III)A |
(I)+(III)B |
(I) + (III)C |
(I) Water Mains Construction |
|
|
|
|
|
|
|
A |
Excavation
of Trench / Breaking up Pavement |
97 |
24 |
|
64 |
64 |
- |
- |
- |
- |
- |
- |
B |
Installation of Pipes and Bedding |
97 |
24 |
|
64 |
64 |
- |
- |
- |
- |
- |
- |
C |
Backfilling |
98 |
24 |
|
65 |
65 |
- |
- |
- |
- |
- |
- |
D |
Reinstating Road Surface |
97 |
24 |
|
65 |
65 |
- |
- |
- |
- |
- |
- |
(II) Demolishment of Pui O Raw Water Pumping
Station |
|
|
|
|
|
A |
General Site Clearance / Demolition Works |
114 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
(III) Construction of Pui O Raw Water Pumping
Station |
|
|
- |
|
- |
- |
- |
- |
A |
Foundation |
113 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
B |
Superstructural Works |
112 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
C |
Installation of E&M Equipment and Commissioning &
Testing |
102 |
- |
|
- |
- |
- |
- |
- |
- |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
List
of Abbreviations: |
|
|
|
|
|
|
|
|
|
|
|
SWL
- Sound Power Level |
|
|
|
|
|
|
|
|
|
|
|
CNL