Noise Mitigation Measures adopted:
Building layout/orientation
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
End Wall
| Innovative Layout: | Noise tolerant portions ( including bathrooms, kitchens, stairwells and lift cores) are arranged to face the noise source |
|---|---|
| Noise Reduction: | About 15 dB(A) |
Noise Tolerant Building/Carpark
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
End Wall
| Noise Tolerant Building: | Building with innovative layout acts as noise shielding structure to protect the residents at the back |
|---|---|
| Noise Reduction: | About 4-7 dB(A) |
End Wall
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
End Wall
| End Wall: | Buildings are orientated with end wall facing the dominant noise source |
|---|---|
| Noise Reduction: | About 2-3 dB(A) |