Noise Mitigation Measures adopted:
Building layout/orientation
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
Innovative Layout: | Noise tolerant portions ( including bathrooms, stairwells and lift cores) are arranged to face the noise source |
---|---|
Noise Reduction: | About 10-15 dB(A) |
Noise Tolerant Building / Carpark
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
Type of Noise Tolerant Building: | A 30m high carpark acts as noise shielding structure to protect the residents at the back |
---|---|
Noise Reduction: | About 5-9 dB(A) |