Noise Mitigation Measures adopted:
Building layout/orientation
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
Noise barrier
End Wall
| Innovative Layout: | Noise tolerant portions ( including corridors and stairwells) are arranged to face the noise source |
|---|---|
| Noise Reduction: | About 5-18 dB(A) |
Noise Tolerant Building / Carpark
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
Noise barrier
End Wall
| Type of Noise Tolerant Building: | Commercial centre acts as noise shielding structure to protect the residents at the back |
|---|---|
| Noise Reduction: | About 5-10 dB(A) |
Vertical Barrier
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
Noise barrier
End Wall
| Dimension of Barrier: | Vertical barrier: 5m high and 15 m in length; Cantilevered barrier: 8m high with a 1m wide cantilevered panel and 115 m in length |
|---|---|
| Materials Selection: | Concrete |
| Noise Reduction: | About 5 dB(A) |
End Wall
Major Noise Source
Target of Protection
Innovative Layout
Noise Tolerant Building
Noise barrier
End Wall
| End Wall: | End wall is arranged to face the noise source |
|---|---|
| Noise Reduction: | About 2-3 dB(A) |